Denon AVR-4802R Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Akustika Denon AVR-4802R. Denon AVR-4802R User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 12
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
- 1 -
DENON AVR/AVC control protocol
Ver. 3.7
Application model : AVR-4802R
Application terminal : RS-232C
Connector specification
Connector type : DB-9pin female type, slave straight connection (DCE type)
( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
Communication format :
Synchronous system : Tone step synchronization
communication system : A half duplex
Communication speed : 9600bps
Character length : 8 bits
Parity control : None
Start bit : 1 bit
Stop bit : 1 bit
Communication procedure : Non procedural
Communication data length : 135 bytes (maximum)
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - Connector specification

- 1 - DENON AVR/AVC control protocol Ver. 3.7 Application model : AVR-4802R Applicatio

Strany 2 - Protocol specification

- 10 - EVENT PARAMETER function example *RES. ZM ON MAIN-ZONE ON/OFF change ZMON<CR> OFF ZMOFF<CR> Z1 PHONO MU

Strany 3 - Others

- 11 - EVENT PARAMETER function example *RES. TF ****** (6 digits) TUNER Frequency change TF105000<CR> --- ****.** kHz at AM

Strany 4 - COMMAND and PARAMETER list

- 12 - EVENT PARAMETER function example *RES. MS DIRECT SURROUND mode change MSDIRECT<CR> PURE DIRECT MSPURE DIRECT<CR&

Strany 5

- 2 - Protocol specification The following three data forms is defined. COMMAND : The message sent to a system(AVR/AVC) from a controller(Touc

Strany 6

- 3 - The example of a command * <CR> is the meaning of 0x0D. SIDVD<CR> : Select Input source DVD MSTHX SURROUND EX<CR>

Strany 7

- 4 - COMMAND and PARAMETER list COMMAND PARAMETER function example PW ON POWER ON/STANDBY change PWON<CR> STANDBY PWSTA

Strany 8

- 5 - COMMAND PARAMETER function example CV SB UP ---SURROUND BACKch (SBch 1SP) CVSB UP<CR> SB DOWN CVSB DOWN<CR&

Strany 9

- 6 - COMMAND PARAMETER function example Z2 PHONO MULTI ZONE -2 mode set , and select source Z2PHONO<CR> | ---The name

Strany 10

- 7 - EVENT PARAMETER function example MS DIRECT SURROUND mode set MSDIRECT<CR> PURE DIRECT MSPURE DIRECT<CR>

Strany 11

- 8 - EVENT PARAMETER function example PS TONE DEFEAT ON PARAMETER setting PSTONE DEFEAT ON<CR> TONE DEFEAT OFF TONE DEFE

Strany 12

- 9 - EVENT(or RESPONSE) and PARAMETER list EVENT PARAMETER function example *RES. PW ON POWER ON/STANDBY change PWON<CR> STA

Komentáře k této Příručce